Skip to Content
Compact PLC, motion and networking

Siemens S7-1200 G2 and Samkoon PLC: task-layered technical selection guide

Compare S7-1200 G2 with Samkoon FGR, FAs and PRO PLC candidates by I/O, motion, PROFINET, safety, expansion and software.

Short answer

What does this page recommend?

A technical alternative, not a drop-in substitute

Samkoon FGR can be a technical candidate for compact I/O control, FAs for higher built-in I/O and Ethernet needs, and PRO for pulse/motion-intensive duties. No equivalence is claimed unless S7-1200 G2 PROFINET, fail-safe, motion, OPC UA and TIA integration requirements are met at exact-CPU level.

Samkoon

ProControl products to evaluate first

The exact configuration is selected after engineering review.

FGRB-C8X8T
Samkoon

FGRB-C8X8T

Compact-duty candidate in the 8 DI/8 NPN transistor DO and four 200 kHz pulse-output class.

Open technical page
FAS-32MT-AC-E
Samkoon

FAS-32MT-AC-E

Machine-PLC candidate in the 16 DI/16 transistor DO, AC supply, Ethernet Modbus TCP/IP and CAN-expansion class.

Open technical page
PRO-C16X16TB
Samkoon

PRO-C16X16TB

Upper-class candidate based on 1 GHz+FPGA for pulse/motion-heavy duties; exact axis and protocol scope is verified.

Open technical page
Technical comparison

Similar requirement, different architecture

The table explains product architectures; it is not an exact order-code selection.

Validation areaSiemens SIMATIC S7-1200 G2Samkoon / ProControl candidate
CPU and program scopeS7-1200 G2 scales memory, performance and interface capacity across CPU 1212C/1214C/1215C G2 classes; exact features depend on the CPU code.FGRB, FAS-32MT-AC-E and PRO occupy different performance/I/O layers. Program memory, cycle time and instruction scope are measured with the running application load.
Built-in I/O and electrical designS7-1200 G2 compact CPU options include built-in DI/DO and analogue functions on some variants; transistor/relay and supply are determined by the full code.FGRB is in the 8/8 class and FAS-32MT-AC-E in the 16/16 transistor class; NPN, SINK/SOURCE, commons, load current and AC/DC supply are verified from diagrams.
Motion and high-speed I/OS7-1200 G2 is positioned with Siemens motion-control architecture and technology objects; axis, kinematics and CPU limits depend on the exact configuration.Official FGRB and FAs pages list 200 kHz pulse outputs; PRO is a candidate for heavier motion. Pulse direction, interpolation, axis count and jitter are proven by PoC.
Industrial network and dataS7-1200 G2 provides PROFINET, Siemens-device integration, web/OPC UA and secure-connectivity functions in a CPU/firmware context.FAS-32MT-AC-E is in the Ethernet Modbus TCP/IP class; exact FGRB and PRO ports are selected separately. PROFINET or OPC UA support is not assumed.
Safety and expansionFail-safe CPU/functions and Siemens expansion architecture in the S7-1200 G2 family can form part of the project's safety integrity.A standard Samkoon PLC is not treated as a safety PLC. Safety is designed with a separately certified relay/PLC; I/O and module-expansion limits are verified per exact model.
Software and migrationS7-1200 G2 is a system comprising hardware, TIA Portal program, technology objects, symbols, diagnostics and any safety project.The SamSoar project is rewritten; Siemens code, function blocks, hardware configuration and safety do not transfer automatically. I/O, timing, motion, communications and fault behaviour are accepted in FAT.
Suitable scenario

When is it worth evaluating?

  • Compact machines where fail-safe and Siemens-specific PROFINET/technology objects are not mandatory
  • New designs where I/O, Modbus TCP and pulse duties can be covered by an exact Samkoon model
  • Modernisations where PLC software, panel wiring and safety architecture can be redesigned
Migration gate

Before making a decision

  1. Record the full S7-1200 G2 CPU, signal/communication modules and firmware version.
  2. Extract program memory, cycle, DI/DO/AI/AO, HSC/PTO, motion axes and safety functions.
  3. Inventory PROFINET devices, telegrams, OPC UA/web/API and diagnostics use.
  4. Verify electrical, performance, expansion and protocol scope for the exact Samkoon model from official sources.
  5. Test I/O, motion, network loss, timing, fault recovery and the safety chain in a wired FAT.
Frequently asked

Clear answers about alternatives and migration

Is this a drop-in replacement?

No. It is not a direct substitute until exact model, electrical, protocol-role, mechanical, software and certification checks pass.

What should I provide for selection?

The exact existing code, diagram or I/O list, PLC/network data, supply, environment and special functions in use.

Can an S7-1200 G2 program be converted to a Samkoon PLC?

No automatic, reliable one-to-one conversion is assumed. Requirements, I/O and state machines are extracted; the program is reimplemented in SamSoar and passes timing and fault tests.

This content compares manufacturer-published data under the same project requirement; it does not guarantee direct substitution or project compatibility. ProControl engineering must validate exact model, revision, protocol, electrical, safety and environmental conditions.

Validate the match with an engineer

Share the exact existing code, I/O list, network and environment so we can identify the right solution without assumptions.

Talk to ProControl