Skip to Content
EC3A-1616A
Solidot · Horizontal IO

EC3A-1616A

Integrated I/O, horizontal style, EtherCAT protocol, 16DI, 16 DO, NPN. Dimensions: 100*96*35mm, space-saving, fast speed, quick wiring, simple configuration, compatiable with mainstream PLC brands such as Mitsubishi, Beckhoff, Omron, etc., simple configuration, protection level IP20.

EtherCATHorizontal IO
ProtocolEtherCAT
Bus Interface2*RJ45
Number of Inputs16

What defines this model

Review the published differences attached to this exact model code rather than only the general family.

Published capability

Ultra-thin, with a height of only 35 mm

Published capability

Based on high-performance EtherCAT ASIC communication chip, parallel interface, fast speed

Published capability

The digital input signal is compatible with NPN and PNP

Published capability

Simple configuration setup, can be cascaded, supports mainstream EtherCAT masters

Place in the system architecture

Treat network, product and field layers as one validation flow.

Control architecture

Network and host-controller compatibility

Complete model code

Channel, interface and function selection

Electrical and installation

Power, connection, environment and mechanical layout

Technical parameters

Values come from Solidot's current official model record and must be reconfirmed for the product revision.

Interface Parameters
ProtocolEtherCAT
Data Transfer MediumUTP or STP of 5 categories or above (STP recommended)
Bus Interface2*RJ45
Data Transfer Rates100 Mbps
Distance Between Stations100m
Electrical IsolationYES
Technical Parameters
Operating Temperature-20~60℃
Power Supply18~36VDC
Relative Humidity95 %, no condensation
Storage Temperature-20~75℃
Protect. ClassIP20
Module Size100×96×35mm
Weight170g
Digital Input
Nominal Voltage24VDC(18V~30V)
Number of Inputs16
Transistor PolarityNPN
Input Current4mA
Electrical Isolation500VAC
IndicatorGreen LED
"0" Signal Voltage15~30 V
“1” Signal Voltage-3~+3 V
Digital Output
Nominal Voltage24VDC(18V~30V)
Number of Outputs16
Transistor PolarityNPN
Load TypeResistive load, inductive load
Max. Output CurrentMax: 500mA
Port ProtectionOvercurrent
Electrical Isolation500VAC
IndicatorGreen LED

Product images

Images are official source records for the same model.

Frequently asked questions

Core checks before selection and commissioning.

Which industrial network does EC3A-1616A support?

Published network support: EtherCAT. Confirm controller compatibility and the complete order code before commissioning.

What are the principal published specifications?

Protocol: EtherCAT; Bus Interface: 2*RJ45; Number of Inputs: 16; Input Current: 4mA

How should this model be selected?

Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.

Other models in this category

Compare protocol, channel architecture and environmental limits.

Manufacturer source

Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record

Validate the right Solidot EC3A-1616A architecture with ProControl

Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.