Skip to Content
PN5R-0808A+
Solidot · Horizontal IO

PN5R-0808A+

Integrated I/O, horizontal type, PROFINET bus, 8-channel digital NPN input and 8-channel digital NPN input & output compatible module, RJ45 communication interface, spring-cage terminals, compact design, fast speed, quick wiring, simple configuration, IP20 protection rating

PROFINETHorizontal IO
ProtocolPROFINET
Bus Interface2×RJ45
Max. Number of IO ModulesDetermined by master station

What defines this model

Review the published differences attached to this exact model code rather than only the general family.

Published capability

Configurable input/output

Published capability

compact design with minimal space occupation

Published capability

optional dust cover

Protocol

PROFINET

Place in the system architecture

Treat network, product and field layers as one validation flow.

Control architecture

Network and host-controller compatibility

Complete model code

Channel, interface and function selection

Electrical and installation

Power, connection, environment and mechanical layout

Technical parameters

Values come from Solidot's current official model record and must be reconfirmed for the product revision.

Interface Parameters
ProtocolPROFINET
Max. Number of IO ModulesDetermined by master station
Data Transfer MediumEthernet CAT5 Cable
Bus Interface2×RJ45
Data Transfer Rates100Mbps
Distance Between Stations≤100m (between stations)
Technical Parameters
Current Consumption50mA
Operating Temperature-20℃~+60℃
Power Supply24VDC (20.4V~28.8V)
Relative Humidity95%, no condensation
Storage Temperature-40℃~+80℃
Protect. ClassIP20
Module Size142×57.3×34mm
Weight150g
Digital Input
Nominal Voltage24VDC (20.4V~28.8V)
Number of Inputs8
Transistor PolarityNPN
Input Current4mA/ch (24VDC)
Electrical Isolation500VAC
IndicatorGreen LED
"0" Signal Voltage-3V~+5V/0.9mA or below
“1” Signal Voltage15V~30V/2.1mA or above
Input FilterNo filter, 0.1ms, 0.2ms, 0.5ms, 1ms, 2ms, 3ms (factory default), 4ms...18ms, 19ms, 20ms
Digital Output
Number of Outputs8
Transistor PolarityNPN
Load TypeResistive, inductive, lamp loads
Max. Output CurrentMax: 0.5A/channel, 3A/8 channels
Port ProtectionShort-circuit protection (auto-recovery)
Electrical Isolation500VAC
IndicatorGreen LED

Product images

Images are official source records for the same model.

Frequently asked questions

Core checks before selection and commissioning.

Which industrial network does PN5R-0808A+ support?

Published network support: PROFINET. Confirm controller compatibility and the complete order code before commissioning.

What are the principal published specifications?

Protocol: PROFINET; Bus Interface: 2×RJ45; Max. Number of IO Modules: Determined by master station; Number of Inputs: 8

How should this model be selected?

Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.

Other models in this category

Compare protocol, channel architecture and environmental limits.

Manufacturer source

Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record

Validate the right Solidot PN5R-0808A+ architecture with ProControl

Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.

Contact engineering