Small in size, compact structure, only 102×72×25 mm

CC4-A08I
Integrated I/O, CC-Link protocol, 8AO, signal current: 0~20 mA / 4~20 mA, measurement error: ±0.1%, size: 102*72*25mm, space-saving, fast speed, fast wiring, pluggable wiring terminals, compatible with Mitsubishi's Q and FX series PLC, simple configuration, IP20 rated protection.
What defines this model
Review the published differences attached to this exact model code rather than only the general family.
Supports digital input delay, can filter out clutter within 1.5ms
Spring-loaded pluggable terminals for quick wiring
Simple configuration setup, can be cascaded, supports mainstream CC-Link master stations such as Mitsubishi
Place in the system architecture
Treat network, product and field layers as one validation flow.
Network and host-controller compatibility
Channel, interface and function selection
Power, connection, environment and mechanical layout
Technical parameters
Values come from Solidot's current official model record and must be reconfirmed for the product revision.
Interface Parameters
| Protocol | CC-Link |
|---|---|
| Data Transfer Medium | CC-Link cable |
| Bus Interface | Push-in Connection |
| Data Transfer Rates | 10 Mbps/5 Mbps/2.5 Mbps/625 kbps/156 kbps |
| Distance Between Stations | ≤100 m/≤160 m/≤400 m/≤900 m/≤1200 m |
| Electrical Isolation | 500V |
Technical Parameters
| Operating Temperature | -10~60℃ |
|---|---|
| Power Supply | 18~36 VDC |
| Relative Humidity | 95 %, no condensation |
| Storage Temperature | -20~75℃ |
| Protect. Class | IP20 |
| Module Size | 102*72*25mm |
| Weight | 150g |
| Power Interface | Push-in Connection |
Analog
| Electrical Isolation | 500V |
|---|---|
| Analog Outputs | 8 |
| Signal Voltage/Current | 0~20 mA / 4~20 mA |
| Resolution | 16 bit |
| Accurate | ±0.1% |
| Indicator | Green LED |
| Signal Type | Current |
| Load Impedance | ≤200 Ω |
Product images
Images are official source records for the same model.

Official files
Only links published by the manufacturer for this model are listed.
Frequently asked questions
Core checks before selection and commissioning.
Which industrial network does CC4-A08I support?
Published network support: CC-Link. Confirm controller compatibility and the complete order code before commissioning.
What are the principal published specifications?
Protocol: CC-Link; Bus Interface: Push-in Connection; Power Interface: Push-in Connection; Analog Outputs: 8
How should this model be selected?
Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.
Other models in this category
Compare protocol, channel architecture and environmental limits.
Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record
Validate the right Solidot CC4-A08I architecture with ProControl
Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.