Small in size, compact structure, only 102×72×25 mm

MT4-A08V
Integrated I/O, Modbus TCP, 8ch AO, multiple measurement range selections, measurement error 0.1%, 102*72*25mm, space-saving, smart, fast wiring, RTB(Removable Terminal Block), easy configuration, suitable for PLCs of Mitsubishi, Siemens, Omron and other major manufacturers, IP20.
What defines this model
Review the published differences attached to this exact model code rather than only the general family.
Built-in switch, dual hundred megabit industrial Ethernet port
Spring-loaded pluggable terminals for quick wiring
Simple configuration setup, can be cascaded, supports mainstream Modbus TCP masters
Place in the system architecture
Treat network, product and field layers as one validation flow.
Network and host-controller compatibility
Channel, interface and function selection
Power, connection, environment and mechanical layout
Technical parameters
Values come from Solidot's current official model record and must be reconfirmed for the product revision.
Interface Parameters
| Protocol | Modbus TCP |
|---|---|
| Max. Number of IO Modules | 127 |
| Data Transfer Medium | CAT5 Ethernet cable |
| Bus Interface | 2*RJ45 |
| Data Transfer Rates | 100Mb/s |
| Distance Between Stations | ≤100m |
Technical Parameters
| Operating Temperature | 0~+55℃ |
|---|---|
| Power Supply | 18~36 VDC |
| Relative Humidity | 95 %, no condensation |
| Storage Temperature | -20~75℃ |
| Protect. Class | IP20 |
| Module Size | 102*72*25mm |
| Weight | About 130g |
| Power Interface | 3 Pin |
| Configuration mode | Through the master station |
Analog
| Electrical Isolation | 500V |
|---|---|
| Analog Outputs | 8 |
| Signal Voltage/Current | -10~+10V (-32768~32767) 0~+10V (0~65535) -10~+10 V (-27648~27648) -5~+5 V (-27648~27648) 1~+5 V (0~27648) 2~+10 V (0~27648) |
| Resolution | 16 bit |
| Accurate | ±0.1% |
| Indicator | Green LED |
| Signal Type | Voltage |
| Load Impedance | ≥2 kΩ |
Product images
Images are official source records for the same model.

Official files
Only links published by the manufacturer for this model are listed.
Frequently asked questions
Core checks before selection and commissioning.
Which industrial network does MT4-A08V support?
Published network support: Modbus TCP. Confirm controller compatibility and the complete order code before commissioning.
What are the principal published specifications?
Protocol: Modbus TCP; Bus Interface: 2*RJ45; Power Interface: 3 Pin; Max. Number of IO Modules: 127
How should this model be selected?
Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.
Other models in this category
Compare protocol, channel architecture and environmental limits.
Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record
Validate the right Solidot MT4-A08V architecture with ProControl
Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.