Skip to Content
MT4-A08V
Solidot · Vertical IO

MT4-A08V

Integrated I/O, Modbus TCP, 8ch AO, multiple measurement range selections, measurement error 0.1%, 102*72*25mm, space-saving, smart, fast wiring, RTB(Removable Terminal Block), easy configuration, suitable for PLCs of Mitsubishi, Siemens, Omron and other major manufacturers, IP20.

Modbus TCPVertical IO
ProtocolModbus TCP
Bus Interface2*RJ45
Power Interface3 Pin

What defines this model

Review the published differences attached to this exact model code rather than only the general family.

Published capability

Small in size, compact structure, only 102×72×25 mm

Published capability

Built-in switch, dual hundred megabit industrial Ethernet port

Published capability

Spring-loaded pluggable terminals for quick wiring

Published capability

Simple configuration setup, can be cascaded, supports mainstream Modbus TCP masters

Place in the system architecture

Treat network, product and field layers as one validation flow.

Control architecture

Network and host-controller compatibility

Complete model code

Channel, interface and function selection

Electrical and installation

Power, connection, environment and mechanical layout

Technical parameters

Values come from Solidot's current official model record and must be reconfirmed for the product revision.

Interface Parameters
ProtocolModbus TCP
Max. Number of IO Modules127
Data Transfer MediumCAT5 Ethernet cable
Bus Interface2*RJ45
Data Transfer Rates100Mb/s
Distance Between Stations≤100m
Technical Parameters
Operating Temperature0~+55℃
Power Supply18~36 VDC
Relative Humidity95 %, no condensation
Storage Temperature-20~75℃
Protect. ClassIP20
Module Size102*72*25mm
WeightAbout 130g
Power Interface3 Pin
Configuration modeThrough the master station
Analog
Electrical Isolation500V
Analog Outputs8
Signal Voltage/Current-10~+10V (-32768~32767) 0~+10V (0~65535) -10~+10 V (-27648~27648) -5~+5 V (-27648~27648) 1~+5 V (0~27648) 2~+10 V (0~27648)
Resolution16 bit
Accurate±0.1%
IndicatorGreen LED
Signal TypeVoltage
Load Impedance≥2 kΩ

Product images

Images are official source records for the same model.

Frequently asked questions

Core checks before selection and commissioning.

Which industrial network does MT4-A08V support?

Published network support: Modbus TCP. Confirm controller compatibility and the complete order code before commissioning.

What are the principal published specifications?

Protocol: Modbus TCP; Bus Interface: 2*RJ45; Power Interface: 3 Pin; Max. Number of IO Modules: 127

How should this model be selected?

Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.

Other models in this category

Compare protocol, channel architecture and environmental limits.

Manufacturer source

Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record

Validate the right Solidot MT4-A08V architecture with ProControl

Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.

Contact engineering