IOL5A-1616CAJ
Solidot · IO-Link Hub

IOL5A-1616CAJ

The IOL5A series signal hub (hereinafter referred to as "HUB") supports IO-Link communication and can accommodate up to 32 channels of digital input or 32 channels of digital output. As an IO-Link slave device, it can connect with IO-Link masters from any brand, enabling users to access process data, diagnostics, and configuration data transmission requirements.

IO-LinkIO-Link Hub
ProtocolIO-Link
Interface typeM12,A-code,4Pin,male connector
Minimum cycle time4.5ms

What defines this model

Review the published differences attached to this exact model code rather than only the general family.

Published capability

Designed in compliance with IO-Link V1.1.3 specification

Published capability

Compatible with various IO-Link standard devices and standard digital signals

Published capability

Features LED status indication, channel protection, and diagnostics

Published capability

Convenient and quick wiring with spring-clamp terminals

Place in the system architecture

Treat network, product and field layers as one validation flow.

Industrial network

PROFINET or EtherNet/IP layer between PLC and master

IO-Link master

Port mode, cycle and process-data management

Sensors and actuators

Process and diagnostic data over standard cabling

Technical parameters

Values come from Solidot's current official model record and must be reconfirmed for the product revision.

Interface Parameters
Interface typeM12,A-code,4Pin,male connector
Cable length≤20m(Between the HUB and the master station)
ProtocolIO-Link
Technical Parameters
Operating Temperature-25℃~+70℃
Power Supply24 VDC(18V~30.2V)
Protect. ClassIP20
Module Size15x53.3x33mm
Functional Parameters
Number of Input Channels16
Input FilteringConfigurable
Input Current5mA/ch(24VDC)
Communication speedCOM3(230.4kbps)
Minimum cycle time4.5ms
Input and output configurableYES
Input channel typeNPN/PNP
Pressure monitoringSupport
Firmware upgradeSupport
Data storageSupport
Number of output channels16
Polarity of output channelNPN

Product images

Images are official source records for the same model.

Frequently asked questions

Core checks before selection and commissioning.

Which industrial network does IOL5A-1616CAJ support?

Published network support: IO-Link. Confirm controller compatibility and the complete order code before commissioning.

What are the principal published specifications?

Protocol: IO-Link; Interface type: M12,A-code,4Pin,male connector; Minimum cycle time: 4.5ms; Number of Input Channels: 16

How should this model be selected?

Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.

Other models in this category

Compare protocol, channel architecture and environmental limits.

Manufacturer source

Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record

Validate the right Solidot IOL5A-1616CAJ architecture with ProControl

Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.

Contact engineering