High IP67 protection rating, suitable for harsh industrial environments

IOL7A-PN01B-8A
The IOL7A-PN01B-8A is an IP67-rated master module of the IOL7A series, serving as an IO-Link master device in standard IO architectures. It features a PROFINET industrial Ethernet interface on the bus side and supports the IO-Link protocol on the user side, functioning as a gateway device that acts as both a bus slave and an IO-Link master. Compatible with equipment from multiple manufacturers, both its bus interface and IO-Link interface offer high interoperability. This provides users with versatile options for data acquisition, system configuration optimization, simplified field wiring, and enhanced system reliability.
What defines this model
Review the published differences attached to this exact model code rather than only the general family.
Based on IO-Link standard V1.1.3, enables remote control of IO-Link slave devices with convenient operation
Features 8 IO-Link ports, supporting connection of up to 8 IO-Link devices (Class-A type)
Pin2 (DO mode) and Pin4 (DO mode) feature short-circuit and overcurrent protection, with Pin2 supporting overcurrent recovery
Place in the system architecture
Treat network, product and field layers as one validation flow.
PROFINET or EtherNet/IP layer between PLC and master
Port mode, cycle and process-data management
Process and diagnostic data over standard cabling
Technical parameters
Values come from Solidot's current official model record and must be reconfirmed for the product revision.
Interface Parameters
| Bus Connection | 2 x M12-D, 4-pin, female ports |
|---|---|
| Protocol | PROFINET |
| Data Transfer Medium | UTP or STP of cat 5 or above (STP is recommended) |
| Data Transfer Rates | 100 Mbps |
| Distance Between Stations | ≤100 m (Distance between stations) |
| Electrical Isolation | 500 V |
Technical Parameters
| Power interface | 2 x M12-L, 5-pin, male & female ports |
|---|---|
| UStotal current | Max:9A |
| USpower consumption | ≤100 mA |
| UA total current | Max:9A |
| UApower consumption | 0 mA |
| Electrical isolation between US and UA | Yes |
| Operating Temperature | -25℃~+70℃ |
| Power Supply | 24 VDC(18V~30V) |
| Relative Humidity | 95%, no condensation |
| Storage Temperature | -40℃~+85℃ |
| Protect. Class | IP67 |
| Module Size | 225.5×62.5×32.6mm |
Functional Parameters
| DI/DO/IO-Link interface | 8 x M12-A, 5-pin, female ports |
|---|---|
| Number of IO-Link channels | 8 |
| IO-Link Transmission Rate | COM1(4.8kbps)、COM2(38.4kbps)、COM3(230.4kbps) |
| Number of Input Channels | 16 |
| Input signal type | PNP |
| Input Filtering | Support, fixed configuration is 3ms |
| Input Current | 200 mA |
| Maximum number of output channels | 16 |
| Maximum current output for single channel | Pin4:0.5A Pin2:2A |
| Output Signal Type | PNP |
| Load Type | Resistive load, inductive load |
| Output Total Current | US、UA max 9 A |
| Port Protection | Overcurrent protection |
| Isolation method | US UA Non-isolated |
| Channel indicator light | Support |
Product images
Images are official source records for the same model.

Official files
Only links published by the manufacturer for this model are listed.
Frequently asked questions
Core checks before selection and commissioning.
Which industrial network does IOL7A-PN01B-8A support?
Published network support: PROFINET, IO-Link. Confirm controller compatibility and the complete order code before commissioning.
What are the principal published specifications?
Protocol: PROFINET; Power interface: 2 x M12-L, 5-pin, male & female ports; DI/DO/IO-Link interface: 8 x M12-A, 5-pin, female ports; Number of IO-Link channels: 8
How should this model be selected?
Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.
Other models in this category
Compare protocol, channel architecture and environmental limits.
Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record
Validate the right Solidot IOL7A-PN01B-8A architecture with ProControl
Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.