Simultaneously connect two protocol masters for communication

GW6L-B0D0(L64)
Slice PROFINET to EtherNet/IP gateway. It can bi-directionally transmit 64 bytes of IO data between PROFINET master station and CC-Link master station, with advantages such as high real-time performance, optimized system configuration, simplified on-site wiring, and improved system reliability. It realizes the communication needs of connecting different networks quickly and efficiently.
What defines this model
Review the published differences attached to this exact model code rather than only the general family.
Data exchange length supports 64 bytes
Compact structure, small space occupancy
High real-time performance, optimized system configuration, simplified field wiring
Place in the system architecture
Treat network, product and field layers as one validation flow.
Vendor protocol and data map
Connectivity, data mapping and diagnostics
Field data delivered to the control system
Technical parameters
Values come from Solidot's current official model record and must be reconfirmed for the product revision.
Interface Parameters
| Bus Connection | 2xRJ45 / 2x4P Spring-clamp teminal block |
|---|---|
| Protocol | PROFINET / CC-Link |
| Data Transfer Medium | EtherCAT CAT5 Cable / CC-Link Cable(Three core shielded twisted wire) |
| Data Transfer Rates | 100 Mbps |
| Distance Between Stations | ≤100 m |
Technical Parameters
| Operating Temperature | -10℃~+60℃ |
|---|---|
| Relative Humidity | 95%, no condensation |
| Storage Temperature | -20℃~+75℃ |
| Protect. Class | IP20 |
| Module Size | 106x61x81 mm |
| Weight | 290g |
Product images
Images are official source records for the same model.

Official files
Only links published by the manufacturer for this model are listed.
Frequently asked questions
Core checks before selection and commissioning.
Which industrial network does GW6L-B0D0(L64) support?
Published network support: EtherCAT, PROFINET, EtherNet/IP, CC-Link. Confirm controller compatibility and the complete order code before commissioning.
What are the principal published specifications?
Protocol: PROFINET / CC-Link; Protect. Class: IP20; Operating Temperature: -10℃~+60℃; Storage Temperature: -20℃~+75℃
How should this model be selected?
Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.
Other models in this category
Compare protocol, channel architecture and environmental limits.
Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record
Validate the right Solidot GW6L-B0D0(L64) architecture with ProControl
Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.