The new generation of slice I/O, high-speed X-bus backplane bus, 16-channel digital input and 16-channel digital output module, NPN&PNP compatible input, default input filter is 3ms, PNP type output. The size is 106*73*25.7mm (installation width is 22.5mm), it occupies a small space and has fast speed. It features quick wiring and pluggable terminal blocks with an IP20 protection level.

Digital Module
Bus InterfaceReed Contact
Input Impedance5.4KΩ
Number of Inputs16

What defines this model

Review the published differences attached to this exact model code rather than only the general family.

Published capability

Input compatible with NPN/PNP type input, convenient for flexible use

Published capability

Input supports type1, type3, the input voltage can go up to 11V, adaptable to more types of sensors

Published capability

Output field measurement supports surge protection, saving the cost of external surge protectors

Published capability

Terminals distinguish between positive and negative poles of power supply to prevent misconnection or reverse connection

Place in the system architecture

Treat network, product and field layers as one validation flow.

Coupler

Control network and backplane bus

I/O modules

Digital, analogue, temperature and special-function channels

Terminals and devices

Power, wiring and field-device matching

Technical parameters

Values come from Solidot's current official model record and must be reconfirmed for the product revision.

Interface Parameters
Data Transfer MediumX-bus Backplane Bus
Bus InterfaceReed Contact
Data Transfer Rates6Mb/s
Electrical IsolationYES
Technical Parameters
Current Consumption100mA
Module Abnormality Self-RecoverySupport
diagnosisSupport
AlarmSupport
Firmware UpgradeSupport
Operating Temperature-20℃~+60℃
Power Supply5VDC(4.5V~5.5V)
Relative Humidity95 %, no condensation
Storage Temperature-40℃~+80℃
Protect. ClassIP20
Module Size106.4*25.7*72.3mm
Weight110g
Digital Input
Reaction Time<50us
Input Impedance5.4KΩ
Power consumption0.5W
Nominal Voltage24VDC(20.4V~28.8V)
Number of Inputs16
Transistor PolarityNPN&PNP
Input Current5mA/ch(24VDC)
Electrical Isolation500VAC
IndicatorGreen LED
"0" Signal Voltage-3V~+5V/below 0.9mA(PNP)11V~30V/above 2.1mA(NPN)
“1” Signal Voltage11V~30V/above 2.1mA(PNP)-3V~+5V/below 0.9mA(NPN)
Input FilterDefault is 3ms, adjustable range is 0~20 ms
Isolation MethodOptocoupler Isolation
Digital Output
Isolation MethodOptocoupler Isolation
Power consumption0.5W
Output Voltage Drop<1V
Leakage Current<10µA
Reaction Time<150µs
Nominal Voltage24VDC(20.4V~28.8V)
Number of Outputs16
Transistor PolarityPNP
Load TypeResistive load, Inductive load, Lamp load
Max. Output CurrentMax:0.5A
Port ProtectionReverse Protection (Automatic Recovery Mechanism), On-site Surge Protection
Electrical Isolation500VAC
IndicatorGreen LED

Product images

Images are official source records for the same model.

Official files

Only links published by the manufacturer for this model are listed.

Frequently asked questions

Core checks before selection and commissioning.

Which industrial network does XB6S-1616B support?

Network support must be confirmed from the exact model code and current official documentation.

What are the principal published specifications?

Bus Interface: Reed Contact; Input Impedance: 5.4KΩ; Number of Inputs: 16; Input Current: 5mA/ch(24VDC)

How should this model be selected?

Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.

Other models in this category

Compare protocol, channel architecture and environmental limits.