Operator interface
Confirm screen class and panel geometry for the machine station.

GX integrated controllers with different display and I/O configurations
Samkoon GX-043-24MT-4AI2AO combines operator interaction, control logic and field I/O in the GX integrated controllers with different display and I/O configurations range. The onboard functions and expansion needs are separated below for practical machine design.
Each point is tied to published model data or an explicit engineering verification step.
Confirm screen class and panel geometry for the machine station.
Confirm input count, output type and electrical load from the exact model record.
Match counting, pulse, temperature and analogue requirements to the published option set.
Ethernet: No
This prevents optional functions from being mistaken for hardware fitted to the main unit.
Review the front panel, rear I/O and connector layout before planning the enclosure.
All source-qualified values are visible by topic; no decision-critical data is hidden behind an expandable panel.
| Panel cut-out | 120 × 94 |
|---|
| Digital I/O | 12 In / 12 Out |
|---|---|
| Analogue I/O | 4 In / 2 Out |
| Total I/O | 30 |
| Ethernet | No |
|---|
These are engineering fit scenarios; final approval depends on project-specific electrical, mechanical and safety checks.
Projects that benefit from combining operator interface, logic and field I/O after the channel structure is verified.
Machine panels designed around one coordinated HMI + PLC engineering workflow.
Applications whose counter or pulse requirements remain inside the published limits of the exact variant.
Panels whose future digital, analogue or temperature expansion is planned before commissioning.
Use these manufacturer records to confirm model identity, lifecycle and the current document revision.
Compare published technical values and the complete model code before selection.
Answers use published values where available and identify the checks that still require the current official record.
The current source has no structured I/O value; confirm it from the complete model suffix.
Confirm these functions against the current model record and project requirement.
Confirm expansion against the main unit, plug-in module and hardware revision.
Ethernet: No
Current product-centre record — Listed in Samkoon's current .cn product centre.
Official sources checked on 24 August 2026. Samkoon current product centre · Exact-model English product record · GX HMI+PLC compatibility record
Share the application, I/O, communication and mounting requirements with our engineering team.