Skip to Content
PN4-GW2MR
Solidot · Serial Communication Module

PN4-GW2MR

This product realizes data communication between PROFINET network and Modbus RTU network, and can connect two Modbus networks to the PROFINET network respectively. It also supports different Modbus communication baud rates and other settings, thus converting Modbus devices into PROFINET devices.

PROFINETModbus RTUSerial Communication Module
ProtocolPROFINET
Serial Interface TypeRS485、RS232、RS422
Max. Number of IO ModulesAccording to the master station

What defines this model

Review the published differences attached to this exact model code rather than only the general family.

Published capability

Implement industrial Ethernet to 2-port serial output

Published capability

Provide RS232/RS485/RS422 three-in-one interface

Published capability

Support Modbus RTU Master&Slave

Protocol

PROFINET

Place in the system architecture

Treat network, product and field layers as one validation flow.

Robot or serial device

Vendor protocol and data map

Solidot gateway

Connectivity, data mapping and diagnostics

PLC network

Field data delivered to the control system

Technical parameters

Values come from Solidot's current official model record and must be reconfirmed for the product revision.

Interface Parameters
Connection Method2*RJ45
ProtocolPROFINET
Max. Number of IO ModulesAccording to the master station
Data Transfer MediumEthernet CAT5 Cable
Data Transfer Rates100Mb/s
Electrical IsolationYes
Technical Parameters
Current Consumption47mA
Rated voltage24VDC(18~36V)
Operating Temperature-10~60℃
Relative Humidity95%, no coagulation
Storage Temperature-20~75℃
Protect. ClassIP20
Module Size102*72*25mm
Weight100g
Functional Parameters
Serial Stop1 , 2
Serial Interface TypeRS485、RS232、RS422
Serial Port ParametersSupported baud rates include: 1200bit/s, 2400bit/s, 4800bit/s, 9600bit/s, 19200bit/s, 38400bit/s, 57600bit/s and 115200bit/s. It can also be adjusted according to needs.
Verification methodNone, odd, even
Data bit7、8、9
Working modeHalf-duplex, full-duplex
Supported TypeModbus Master and Modbus Slave
Function codeAs a Modbus master, it supports function codes 01H, 02H, 03H, 04H, 05H, 06H, 0FH and 10H

Product images

Images are official source records for the same model.

Frequently asked questions

Core checks before selection and commissioning.

Which industrial network does PN4-GW2MR support?

Published network support: PROFINET, Modbus RTU. Confirm controller compatibility and the complete order code before commissioning.

What are the principal published specifications?

Protocol: PROFINET; Serial Interface Type: RS485、RS232、RS422; Max. Number of IO Modules: According to the master station; Protect. Class: IP20

How should this model be selected?

Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.

Other models in this category

Compare protocol, channel architecture and environmental limits.

Manufacturer source

Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record

Validate the right Solidot PN4-GW2MR architecture with ProControl

Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.

Contact engineering