Implement industrial Ethernet to 2-port serial output

PN4-GW2FP
Realize data communication between PROFINET network and serial communication protocol network, can connect two RS232, RS485, RS422 serial devices to PROFINET network respectively, and support different communication baud rates and other settings. Convert the serial communication protocol device into a PROFINET network device.
What defines this model
Review the published differences attached to this exact model code rather than only the general family.
Provide RS232/RS485/RS422 three-in-one interface
Support Freeport, protocol packet assembly, transparent transmission
PROFINET
Place in the system architecture
Treat network, product and field layers as one validation flow.
Vendor protocol and data map
Connectivity, data mapping and diagnostics
Field data delivered to the control system
Technical parameters
Values come from Solidot's current official model record and must be reconfirmed for the product revision.
Interface Parameters
| Connection Method | 2*RJ45 |
|---|---|
| Protocol | PROFINET |
| Max. Number of IO Modules | According to the master station |
| Data Transfer Medium | Ethernet CAT5 Cable |
| Data Transfer Rates | 100Mb/s |
| Electrical Isolation | Yes |
Technical Parameters
| Current Consumption | 47mA |
|---|---|
| Rated voltage | 24VDC(18~36V) |
| Operating Temperature | -10~60℃ |
| Relative Humidity | 95%, no coagulation. |
| Storage Temperature | -20~75℃ |
| Protect. Class | IP20 |
| Module Size | 102*72*25mm |
| Weight | 100g |
Functional Parameters
| Serial Stop | 1, 2 bit |
|---|---|
| Serial Interface Type | RS485、RS232、RS422 |
| Support mode | Master-slave mode and producer-consumer mode (not supported by RS485) |
| The number of commands for master-slave mode switching | The maximum support for adding 500 exchange commands |
| The number of commands exchanged in the producer-consumer pattern | The maximum number of supported exchange commands is 1000, and the maximum number of elements supported is 2000 |
| Serial Port Parameters | Supported baud rates include: 1200bit/s, 2400bit/s, 4800bit/s, 9600bit/s, 19200bit/s, 35700bit/s, 38400bit/s, 57600bit/s and 115200bit/s. Other baud rates can also be customized as needed. |
| Verification method | Odd, even, none |
| Data bit | 7、8 bit |
Product images
Images are official source records for the same model.

Official files
Only links published by the manufacturer for this model are listed.
Frequently asked questions
Core checks before selection and commissioning.
Which industrial network does PN4-GW2FP support?
Published network support: PROFINET. Confirm controller compatibility and the complete order code before commissioning.
What are the principal published specifications?
Protocol: PROFINET; Serial Interface Type: RS485、RS232、RS422; Max. Number of IO Modules: According to the master station; Protect. Class: IP20
How should this model be selected?
Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.
Other models in this category
Compare protocol, channel architecture and environmental limits.
Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record
Validate the right Solidot PN4-GW2FP architecture with ProControl
Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.