PN4-GW2FP
Solidot · Serial Communication Module

PN4-GW2FP

Realize data communication between PROFINET network and serial communication protocol network, can connect two RS232, RS485, RS422 serial devices to PROFINET network respectively, and support different communication baud rates and other settings. Convert the serial communication protocol device into a PROFINET network device.

PROFINETSerial Communication Module
ProtocolPROFINET
Serial Interface TypeRS485、RS232、RS422
Max. Number of IO ModulesAccording to the master station

What defines this model

Review the published differences attached to this exact model code rather than only the general family.

Published capability

Implement industrial Ethernet to 2-port serial output

Published capability

Provide RS232/RS485/RS422 three-in-one interface

Published capability

Support Freeport, protocol packet assembly, transparent transmission

Protocol

PROFINET

Place in the system architecture

Treat network, product and field layers as one validation flow.

Robot or serial device

Vendor protocol and data map

Solidot gateway

Connectivity, data mapping and diagnostics

PLC network

Field data delivered to the control system

Technical parameters

Values come from Solidot's current official model record and must be reconfirmed for the product revision.

Interface Parameters
Connection Method2*RJ45
ProtocolPROFINET
Max. Number of IO ModulesAccording to the master station
Data Transfer MediumEthernet CAT5 Cable
Data Transfer Rates100Mb/s
Electrical IsolationYes
Technical Parameters
Current Consumption47mA
Rated voltage24VDC(18~36V)
Operating Temperature-10~60℃
Relative Humidity95%, no coagulation.
Storage Temperature-20~75℃
Protect. ClassIP20
Module Size102*72*25mm
Weight100g
Functional Parameters
Serial Stop1, 2 bit
Serial Interface TypeRS485、RS232、RS422
Support modeMaster-slave mode and producer-consumer mode (not supported by RS485)
The number of commands for master-slave mode switchingThe maximum support for adding 500 exchange commands
The number of commands exchanged in the producer-consumer patternThe maximum number of supported exchange commands is 1000, and the maximum number of elements supported is 2000
Serial Port ParametersSupported baud rates include: 1200bit/s, 2400bit/s, 4800bit/s, 9600bit/s, 19200bit/s, 35700bit/s, 38400bit/s, 57600bit/s and 115200bit/s. Other baud rates can also be customized as needed.
Verification methodOdd, even, none
Data bit7、8 bit

Product images

Images are official source records for the same model.

Frequently asked questions

Core checks before selection and commissioning.

Which industrial network does PN4-GW2FP support?

Published network support: PROFINET. Confirm controller compatibility and the complete order code before commissioning.

What are the principal published specifications?

Protocol: PROFINET; Serial Interface Type: RS485、RS232、RS422; Max. Number of IO Modules: According to the master station; Protect. Class: IP20

How should this model be selected?

Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.

Other models in this category

Compare protocol, channel architecture and environmental limits.