Skip to Content
XB6S-P2000
Solidot · Auxiliary Module

XB6S-P2000

New Generation slice I/O expansion power module 2A

Auxiliary Module
Bus InterfaceReed Contact
Input Voltage24VDC(18V~36V)
Input CurrentMax:600mA(24VDC)

What defines this model

Review the published differences attached to this exact model code rather than only the general family.

Published capability

New Generation slice I/O expansion power module 2A

Bus Interface

Reed Contact

Input Voltage

24VDC(18V~36V)

Input Current

Max:600mA(24VDC)

Place in the system architecture

Treat network, product and field layers as one validation flow.

Coupler

Control network and backplane bus

I/O modules

Digital, analogue, temperature and special-function channels

Terminals and devices

Power, wiring and field-device matching

Technical parameters

Values come from Solidot's current official model record and must be reconfirmed for the product revision.

Interface Parameters
Data Transfer MediumX-bus Backplane Bus
Bus InterfaceReed Contact
Data Transfer Rates6Mb/s
Distance Between Stations22.5mm (station to station)
Electrical IsolationYes
Technical Parameters
Input Voltage24VDC(18V~36V)
Input CurrentMax:600mA(24VDC)
Backplane power supply currentMax:2A
Backplane power supply voltage5VDC
Operating Temperature-20℃~+60℃
Relative Humidity95 %, no condensation
Storage Temperature-40℃~+80℃
Protect. ClassIP20
Module Size106.4*25.7*72.3mm
Weight110g

Product images

Images are official source records for the same model.

Official files

Only links published by the manufacturer for this model are listed.

Frequently asked questions

Core checks before selection and commissioning.

Which industrial network does XB6S-P2000 support?

Network support must be confirmed from the exact model code and current official documentation.

What are the principal published specifications?

Bus Interface: Reed Contact; Input Voltage: 24VDC(18V~36V); Input Current: Max:600mA(24VDC); Backplane power supply current: Max:2A

How should this model be selected?

Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.

Other models in this category

Compare protocol, channel architecture and environmental limits.

Manufacturer source

Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record

Validate the right Solidot XB6S-P2000 architecture with ProControl

Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.

Contact engineering