Occupies small space, fast speed, quick wiring, pluggable terminal blocks

XB6-CT2002ST
XB6-CT2002ST, fileldbus I/O, CClink IE TSN coupler, distributed I/O, remote I/O, CClink IE TSN I/O, sliced I/O, DI, DO, AI, AO, X-bus
What defines this model
Review the published differences attached to this exact model code rather than only the general family.
Configuration is simple, compatible with Mitsubishi and other CC-Link IE TSN master stations
High-speed X-bus bus, full load of 32 slave stations, maximum scan cycle 1ms
CC-Link IE TSN
Place in the system architecture
Treat network, product and field layers as one validation flow.
Control network and backplane bus
Digital, analogue, temperature and special-function channels
Power, wiring and field-device matching
Technical parameters
Values come from Solidot's current official model record and must be reconfirmed for the product revision.
Interface Parameters
| Protocol | CC-Link IE TSN |
|---|---|
| Max. Number of IO Modules | 32 |
| Data Transfer Medium | CAT5 Ethernet cable |
| Bus Interface | 2*RJ45 |
| Data Transfer Rates | 1GB/s |
| Distance Between Stations | 100m |
| Electrical Isolation | YES |
Technical Parameters
| Current Consumption | 1600mA ( subsequent IO modules) |
|---|---|
| Operating Temperature | -10~60℃ |
| Power Supply | 24VDC(18~36V) |
| Relative Humidity | 95 %, no condensation |
| Storage Temperature | -20~75℃ |
| Protect. Class | IP20 |
| Module Size | 106*61*47mm |
| Weight | approximate 300g |
| Power Interface | 3-pin spring clamp connector |
Product images
Images are official source records for the same model.

Official files
Only links published by the manufacturer for this model are listed.
Frequently asked questions
Core checks before selection and commissioning.
Which industrial network does XB6-CT2002ST support?
Published network support: CC-Link IE TSN, CC-Link. Confirm controller compatibility and the complete order code before commissioning.
What are the principal published specifications?
Protocol: CC-Link IE TSN; Bus Interface: 2*RJ45; Power Interface: 3-pin spring clamp connector; Max. Number of IO Modules: 32
How should this model be selected?
Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.
Other models in this category
Compare protocol, channel architecture and environmental limits.
Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record
Validate the right Solidot XB6-CT2002ST architecture with ProControl