Occupies small space, fast speed, quick wiring, pluggable terminal blocks

XB6-MT2002ST
Modbus TCP Coupler Kit: Contains Modbus TCP coupler (XB6-MT0002), 2A power (XB6-P2000H), Terminal cover plate ( XB6-CVR00) ; 2-way Modbus TCP bus interface, in, out and 1-way backplane X-bus interface, 106*61*47mm, can provide 2000mA drive current for coupler and subsequent IO modules. space saving, smart, fast wiring, RTB(Removable Terminal Block), easy configuration, web configuration, Supports function codes 01/02/03/04/05/15/16/23, suitable for Schneider, Siemens, Keyence and other master stations, high speed X-bus, full load 32 slave stations, scanning cycle as low as 1ms, IP20.
What defines this model
Review the published differences attached to this exact model code rather than only the general family.
Simple web page configuration function, supports 01/02/03/04/05/15/16/23 function codes
Compatible with mainstream Modbus TCP masters such as Schneider, Siemens, Keyence etc.
Uses X-bus backplane bus: maximum scan cycle is 1ms
Place in the system architecture
Treat network, product and field layers as one validation flow.
Control network and backplane bus
Digital, analogue, temperature and special-function channels
Power, wiring and field-device matching
Technical parameters
Values come from Solidot's current official model record and must be reconfirmed for the product revision.
Interface Parameters
| Protocol | Modbus TCP |
|---|---|
| Max. Number of IO Modules | 32 |
| Data Transfer Medium | CAT5 Ethernet cable |
| Data Transfer Rates | 100Mb/s |
| Distance Between Stations | 100m |
| Electrical Isolation | 500V |
Technical Parameters
| Operating Temperature | -10~60℃ |
|---|---|
| Power Supply | 24VDC(18~36V) |
| Relative Humidity | 95 %, no condensation |
| Storage Temperature | -20~75℃ |
| Protect. Class | IP20 |
| Module Size | 106*61*47mm |
| Weight | approximate 300g |
| Power Interface | 3Pin push-in |
Product images
Images are official source records for the same model.

Official files
Only links published by the manufacturer for this model are listed.
Frequently asked questions
Core checks before selection and commissioning.
Which industrial network does XB6-MT2002ST support?
Published network support: Modbus TCP. Confirm controller compatibility and the complete order code before commissioning.
What are the principal published specifications?
Protocol: Modbus TCP; Power Interface: 3Pin push-in; Max. Number of IO Modules: 32; Power Supply: 24VDC(18~36V)
How should this model be selected?
Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.
Other models in this category
Compare protocol, channel architecture and environmental limits.
Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record
Validate the right Solidot XB6-MT2002ST architecture with ProControl
Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.