VFD200 Smart Mini AC Drive
VFD200 is a compact V/f drive for basic speed control in small machines. The single-phase 220 V and three-phase 380 V variants cover different power ranges; selection should follow the exact model and motor current. A keypad, terminal control and RS485 connectivity are documented.

Technical specifications
Ratings refer to the linked document revision. Confirm the nameplate, motor current and operating conditions for the exact selection.
Motor and process control
| Control method | Control method: V/f. PDF p. 1 |
|---|---|
| Stopping options | Coast stop, deceleration stop and deceleration with DC braking are shown. PDF p. 1 |
Electrical ratings
| Output frequency | Output frequency: 0.00–400.00 Hz. PDF p. 1 |
|---|---|
| Single-phase models | Single-phase 220 V models: 0.4–2.2 kW. PDF p. 1 |
| Three-phase models | Three-phase 380 V models: 0.75–3.7 kW. PDF p. 1 |
Commissioning and operation
| Motor autotuning | Motor-parameter self-learning is listed. PDF p. 1 |
|---|---|
| Command sources | Select the speed source with P0-01 and command source with P0-02. PDF p. 1 |
| Acceleration / deceleration | Acceleration/deceleration are adjusted with P0-04/P0-05. PDF p. 1 |
Communication and options
| RS485 connection | RS485 communication is listed as standard. PDF p. 1 |
|---|---|
| Remote keypad | The RJ45 remote-control interface is specified for up to 100 m; it is not identified as Ethernet. PDF p. 1 |
Operation
| Operator keypad | Rotary-control LED keypad. PDF p. 1 |
|---|
Control inputs and outputs
| Digital inputs | The wiring diagram shows digital inputs X1–X5. PDF p. 1 |
|---|---|
| Analogue inputs | The diagram shows a potentiometer input at AI1 and selectable 0–10 V / 0–20 mA at AI2. PDF p. 1 |
| Analogue output | AO is jumper-selectable for 0–10 V or 0–20 mA; its default function is operating frequency. PDF p. 1 |
| Relay output | The ROA/ROB/ROC relay defaults to fault indication. PDF p. 1 |
| Run output | The diagram shows Y1 as a run-command output; load rating is not provided. PDF p. 1 |
Protection functions
| Protection functions | Undervoltage, overcurrent, overtemperature and ground short-circuit protection are listed. PDF p. 1 |
|---|
Installation and cooling
| Cooling | An independent duct separates the heatsink and control section; cooling is forced-air. PDF p. 1 |
|---|
Model and dimension tables
Check the units and document revision in each table. Wide tables can be scrolled horizontally on small screens.
Model and current options
Evaluate single- and three-phase supply variants separately. Match the motor nameplate current to the selected drive’s output current.
| Model code | Supply / voltage class | Motor power | Rated output current | Source |
|---|---|---|---|---|
| VFD200-0R4GS2 | 1 phase, 220 V | 0.4 kW | 2.3 A | PDF p. 1 |
| VFD200-R75GS2 | 1 phase, 220 V | 0.75 kW | 4 A | PDF p. 1 |
| VFD200-1R5GS2 | 1 phase, 220 V | 1.5 kW | 7 A | PDF p. 1 |
| VFD200-2R2GS2 | 1 phase, 220 V | 2.2 kW | 9.6 A | PDF p. 1 |
| VFD200-R75GT4 | 3 phase, 380 V | 0.75 kW | 2.1 A | PDF p. 1 |
| VFD200-1R5GT4 | 3 phase, 380 V | 1.5 kW | 3.8 A | PDF p. 1 |
| VFD200-2R2GT4 | 3 phase, 380 V | 2.2 kW | 5.1 A | PDF p. 1 |
| VFD200-3R7GT4 | 3 phase, 380 V | 3.7 kW | 9 A | PDF p. 1 |
Document revision and selection notes
This document does not specify overload duration, ambient limits or altitude derating
This document does not specify overload duration, ambient limits or altitude derating. A braking-resistor symbol does not establish an internal brake unit on every model.
PDF p. 1
The manufacturer’s “user manual” link resolves to a one-page brochure
The manufacturer’s “user manual” link resolves to a one-page brochure. VFD200A is a separate family and its figures were not substituted.
PDF p. 1
The brochure row labelled 0.75–3.7 kW gives L/W/H as 152 / 89 / 123 mm, mounting pitches 141 × 80.5 mm and hole diameter 5.2 mm
The brochure row labelled 0.75–3.7 kW gives L/W/H as 152 / 89 / 123 mm, mounting pitches 141 × 80.5 mm and hole diameter 5.2 mm. Do not automatically apply it to the 0.4 kW model.
PDF p. 1
Manufacturer drawings
Open connection and dimension drawings in the manufacturer’s original PDF. For installation, use the complete manual matching the exact product model.
PDF p. 1
Information needed for selection
Providing the following information helps our technical team select the correct product and accessories.
- What does the complete motor nameplate state: phase, voltage, rated current, power and motor type?
- What starting torque, braking requirement and duty cycle does the load require?
- Will control use terminals, an analogue signal, communications or encoder feedback?
- What are the cabinet temperature, altitude, motor-cable length and available mounting space?
Let us verify your application
For VFD200 Smart Mini AC Drive selection, share motor, supply, control, environment and duty-cycle data with our engineering team.