VFD200 is a compact V/f drive for basic speed control in small machines. The single-phase 220 V and three-phase 380 V variants cover different power ranges; selection should follow the exact model and motor current. A keypad, terminal control and RS485 connectivity are documented.

VFD200 Smart Mini AC Drive

Technical specifications

Ratings refer to the linked document revision. Confirm the nameplate, motor current and operating conditions for the exact selection.

Motor and process control

Control method
Control method: V/f.
PDF p. 1
Stopping options
Coast stop, deceleration stop and deceleration with DC braking are shown.
PDF p. 1

Electrical ratings

Output frequency
Output frequency: 0.00–400.00 Hz.
PDF p. 1
Single-phase models
Single-phase 220 V models: 0.4–2.2 kW.
PDF p. 1
Three-phase models
Three-phase 380 V models: 0.75–3.7 kW.
PDF p. 1

Commissioning and operation

Motor autotuning
Motor-parameter self-learning is listed.
PDF p. 1
Command sources
Select the speed source with P0-01 and command source with P0-02.
PDF p. 1
Acceleration / deceleration
Acceleration/deceleration are adjusted with P0-04/P0-05.
PDF p. 1

Communication and options

RS485 connection
RS485 communication is listed as standard.
PDF p. 1
Remote keypad
The RJ45 remote-control interface is specified for up to 100 m; it is not identified as Ethernet.
PDF p. 1

Operation

Operator keypad
Rotary-control LED keypad.
PDF p. 1

Control inputs and outputs

Digital inputs
The wiring diagram shows digital inputs X1–X5.
PDF p. 1
Analogue inputs
The diagram shows a potentiometer input at AI1 and selectable 0–10 V / 0–20 mA at AI2.
PDF p. 1
Analogue output
AO is jumper-selectable for 0–10 V or 0–20 mA; its default function is operating frequency.
PDF p. 1
Relay output
The ROA/ROB/ROC relay defaults to fault indication.
PDF p. 1
Run output
The diagram shows Y1 as a run-command output; load rating is not provided.
PDF p. 1

Protection functions

Protection functions
Undervoltage, overcurrent, overtemperature and ground short-circuit protection are listed.
PDF p. 1

Installation and cooling

Cooling
An independent duct separates the heatsink and control section; cooling is forced-air.
PDF p. 1

Model and dimension tables

Check the units and document revision in each table. Wide tables can be scrolled horizontally on small screens.

Model and current options

Evaluate single- and three-phase supply variants separately. Match the motor nameplate current to the selected drive’s output current.

Model codeSupply / voltage classMotor powerRated output currentSource
VFD200-0R4GS21 phase, 220 V0.4 kW2.3 APDF p. 1
VFD200-R75GS21 phase, 220 V0.75 kW4 APDF p. 1
VFD200-1R5GS21 phase, 220 V1.5 kW7 APDF p. 1
VFD200-2R2GS21 phase, 220 V2.2 kW9.6 APDF p. 1
VFD200-R75GT43 phase, 380 V0.75 kW2.1 APDF p. 1
VFD200-1R5GT43 phase, 380 V1.5 kW3.8 APDF p. 1
VFD200-2R2GT43 phase, 380 V2.2 kW5.1 APDF p. 1
VFD200-3R7GT43 phase, 380 V3.7 kW9 APDF p. 1

Document revision and selection notes

This document does not specify overload duration, ambient limits or altitude derating

This document does not specify overload duration, ambient limits or altitude derating. A braking-resistor symbol does not establish an internal brake unit on every model.
PDF p. 1

The manufacturer’s “user manual” link resolves to a one-page brochure

The manufacturer’s “user manual” link resolves to a one-page brochure. VFD200A is a separate family and its figures were not substituted.
PDF p. 1

The brochure row labelled 0.75–3.7 kW gives L/W/H as 152 / 89 / 123 mm, mounting pitches 141 × 80.5 mm and hole diameter 5.2 mm

The brochure row labelled 0.75–3.7 kW gives L/W/H as 152 / 89 / 123 mm, mounting pitches 141 × 80.5 mm and hole diameter 5.2 mm. Do not automatically apply it to the 0.4 kW model.
PDF p. 1

Manufacturer drawings

Open connection and dimension drawings in the manufacturer’s original PDF. For installation, use the complete manual matching the exact product model.

Open drawing in PDF
VFD200 — models, wiring and dimensions
PDF p. 1

Information needed for selection

Providing the following information helps our technical team select the correct product and accessories.

  • What does the complete motor nameplate state: phase, voltage, rated current, power and motor type?
  • What starting torque, braking requirement and duty cycle does the load require?
  • Will control use terminals, an analogue signal, communications or encoder feedback?
  • What are the cabinet temperature, altitude, motor-cable length and available mounting space?

Let us verify your application

For VFD200 Smart Mini AC Drive selection, share motor, supply, control, environment and duty-cycle data with our engineering team.

Request a technical review