Skip to Content
Veikong · Economic AC Drives

VFD500M Compact Vector AC Drive

VFD500M is an economical drive offering V/f or sensorless vector control for small and medium induction-motor applications. I/O count and cooling differ by frame. A single terminal configuration or maximum-frequency claim should not be applied to every model.

VFD500M Compact Vector AC Drive

Technical specifications

Ratings refer to the linked document revision. Confirm the nameplate, motor current and operating conditions for the exact selection.

Motor and process control

Control modes
V/f and sensorless vector; speed and torque control in SVC mode.
PDF p. 8
Speed range
Speed range: V/f 1:100, SVC 1:200.
PDF p. 8
Speed accuracy
Speed accuracy: V/f ±0.5%; SVC ±0.2%.
PDF p. 8
Frequency resolution
Digital frequency setting resolution: 0.01 Hz.
PDF p. 9
Ramp settings
Linear/S-curve, four time groups, acceleration/deceleration 0–60000 s.
PDF p. 9
Application functions
PID, sleep/wake, 16-speed operation and two motor parameter groups.
PDF p. 9

Electrical ratings

Supply options
220 V class 200–240 V; three-phase 380 V class 380–480 V.
PDF p. 8
Supply tolerance
Voltage tolerance −15%/+10%; 50/60 Hz input, frequency variation <5%.
PDF p. 8
Switching frequency
Switching frequency 1–16 kHz depending on model.
PDF p. 9

Technical specifications

Overload capacity
Manual: heavy duty 150%/60 s; light duty 120%/60 s.
PDF p. 8

Communication and options

Communications
Modbus communication is standard.
PDF p. 9

Control inputs and outputs

Frame A inputs
Frame A: four digital and one analogue input.
PDF p. 9
Frame B inputs
Frame B: five DI including a 50 kHz pulse input; two AI support 0–10 V / 0–20 mA.
PDF p. 9
Frame A outputs
Frame A: one DO, one normally-open relay and one AO.
PDF p. 9

Installation and cooling

Cooling
Frame A is naturally cooled; frame B is fan cooled.
PDF p. 10
Environmental conditions
IP20; nominal −10…+40 °C, derated up to +50 °C at 1.5% current reduction per additional degree.
PDF p. 10
Altitude and derating
0–3000 m; above 1000 m derate current by 1% per 100 m.
PDF p. 10
Humidity and storage
Humidity <95%, non-condensing; storage −20…+60 °C.
PDF p. 10

Model and dimension tables

Check the units and document revision in each table. Wide tables can be scrolled horizontally on small screens.

Model and current options

Match the input supply and heavy/light-duty current to the motor. Check the complete product code when selecting the enclosure and I/O.

Model codeSupply / voltage classMotor powerHeavy-duty output currentLight-duty currentSource
VFD500M-R75GT4B3 phase, 380 V0.75 kW2.5 A4.2 APDF p. 8
VFD500M-1R5GT4B3 phase, 380 V1.5 kW4.2 A5.6 APDF p. 8
VFD500M-2R2GT4B3 phase, 380 V2.2 kW5.6 A9.4 APDF p. 8
VFD500M-4R0GT4B3 phase, 380 V3.7 kW9.4 A10.5 APDF p. 8
VFD500M-5R5GT4B3 phase, 380 V5.5 kW13 A17 APDF p. 8
VFD500M-7R5GT4B3 phase, 380 V7.5 kW17 A23 APDF p. 8
VFD500M-R40GS2B1 phase, 220 V0.4 kW2.8 A3.2 APDF p. 8
VFD500M-R75GS2B1 phase, 220 V0.75 kW4.5 A4.8 APDF p. 8
VFD500M-1R5GS2B1 phase, 220 V1.5 kW8 A10.6 APDF p. 8
VFD500M-2R2GS2B1 phase, 220 V2.2 kW10.6 A12.5 APDF p. 8
VFD500M-R40GT2B3 phase, 220 V0.4 kW2.8 A3.2 APDF p. 8
VFD500M-R75GT2B3 phase, 220 V0.75 kW4.5 A4.8 APDF p. 8
VFD500M-1R5GT2B3 phase, 220 V1.5 kW8 A10.6 APDF p. 8
VFD500M-2R2GT2B3 phase, 220 V2.2 kW10.6 A12.5 APDF p. 8
Enclosure and mounting dimensions

Compare the full product code and enclosure drawing before installation. Dimensions can differ between hardware revisions.

ScopeWidthHeightDepthMounting pitchesHole diameterSource
Frame A75 mm145 mm115 mm66 × 137 mm5 mmPDF p. 11
Frame B86 mm175 mm128 mm72 × 165 mm5 mmPDF p. 11
Frame C120 mm235 mm158 mm108 × 225 mm5 mmPDF p. 11

Document revision and selection notes

The V1.1 / October 2020 manual gives dimensions by frame

The V1.1 / October 2020 manual gives dimensions by frame. Model-to-frame mapping and input currents conflict with the newer brochure, so confirm the ordered nameplate.
PDF p. 8

V1.1 manual: 600 Hz V/f; brochure: 3000 Hz; page prose also mentions 2000 Hz

V1.1 manual: 600 Hz V/f; brochure: 3000 Hz; page prose also mentions 2000 Hz. Do not publish a universal maximum without firmware/nameplate confirmation.
PDF p. 9PDF p. 1

The brochure groups single-phase 1.5/2.2 kW into frame-A dimensions; the manual puts them in frame B

The brochure groups single-phase 1.5/2.2 kW into frame-A dimensions; the manual puts them in frame B. Three-phase input currents also differ.
PDF p. 8PDF p. 11PDF p. 1

The brochure gives SVC torque 150%/0.5 Hz and short overload 180%/3 s; the manual gives SVC torque 180%/0.25 Hz.

The brochure gives SVC torque 150%/0.5 Hz and short overload 180%/3 s; the manual gives SVC torque 180%/0.25 Hz.
PDF p. 9PDF p. 1

The summary lists one DO and one pulse output separately, but the B/C wiring diagram shows only HDO

The summary lists one DO and one pulse output separately, but the B/C wiring diagram shows only HDO. Do not promise two separate digital outputs without checking the physical board.
PDF p. 9PDF p. 12

Conflicting/revision-specific document information; confirm the ordered unit: V1.1 manual: V/f 0–600 Hz, SVC 0–200 Hz

Conflicting/revision-specific document information; confirm the ordered unit: V1.1 manual: V/f 0–600 Hz, SVC 0–200 Hz. This conflicts with the newer brochure’s 3000 Hz claim.
PDF p. 9

Important note 7

Conflicting/revision-specific document information; confirm the ordered unit: The manual specifies V/f 150% at 0.5 Hz; SVC 180% at 0.25 Hz.
PDF p. 9

Important note 8

Conflicting/revision-specific document information; confirm the ordered unit: The frame B/C wiring diagram shows an HDO digital/pulse output, NO/NC relay and one AO; the summary table’s separate DO wording is ambiguous.
PDF p. 12

Manufacturer drawings

Open connection and dimension drawings in the manufacturer’s original PDF. For installation, use the complete manual matching the exact product model.

Open drawing in PDF
VFD500M — frame A/B/C dimensions
PDF p. 11

Information needed for selection

Providing the following information helps our technical team select the correct product and accessories.

  • What does the complete motor nameplate state: phase, voltage, rated current, power and motor type?
  • What starting torque, braking requirement and duty cycle does the load require?
  • Will control use terminals, an analogue signal, communications or encoder feedback?
  • What are the cabinet temperature, altitude, motor-cable length and available mounting space?

Let us verify your application

For VFD500M Compact Vector AC Drive selection, share motor, supply, control, environment and duty-cycle data with our engineering team.

Request a technical review