Skip to Content
Veikong · General Purpose AC Drives

VFD530 High Performance AC Drive

VFD530 provides speed and torque control for induction and permanent-magnet synchronous motors. It offers V/f, sensorless vector and feedback vector operation with an appropriate PG card. Network/encoder boards, heavy/light-duty current ratings and manual revision must be selected together with the motor.

VFD530 High Performance AC Drive

Technical specifications

Ratings refer to the linked document revision. Confirm the nameplate, motor current and operating conditions for the exact selection.

Motor and process control

Supported motors
Induction and permanent-magnet synchronous motors.
PDF p. 2
Control modes
V/f, sensorless vector without PG (SVC), feedback vector with PG card (VC).
PDF p. 10
Speed and torque
Speed control; torque control in SVC and VC modes.
PDF p. 10
Speed range
Speed ranges: V/f 1:100, SVC 1:200, VC 1:1000.
PDF p. 10
Speed accuracy
Speed accuracy: V/f ±0.5%, SVC ±0.2%, VC ±0.02%.
PDF p. 10
Speed response
Speed response: V/f 5 Hz, SVC 20 Hz, VC 50 Hz.
PDF p. 10
Setting resolution
Digital frequency resolution is 0.01 Hz; analogue setting resolution is 0.1% of maximum frequency.
PDF p. 10
Ramp settings
Four acceleration/deceleration groups; linear and S-curve, 0–60000 s.
PDF p. 10
Application functions
Process PID, sleep/wake, 16-speed operation, virtual I/O and two motor parameter groups are listed.
PDF p. 10
Starting / stopping
Direct and flying start; deceleration or coast stop; DC-braking options.
PDF p. 10

Electrical ratings

Supply voltage
220 V class: 200–240 V; 380 V class: three-phase 380–480 V.
PDF p. 9
Supply tolerance
Voltage variation −15% / +10%; 50/60 Hz supply with frequency variation <5%.
PDF p. 9
Switching frequency
Switching frequency 1–12 kHz depending on model.
PDF p. 10

Technical specifications

Overload capacity
General-purpose heavy duty: 150% current for 60 s; light duty: 120% for 60 s.
PDF p. 9PDF p. 10

Control inputs and outputs

Digital inputs
Five standard digital inputs; one accepts pulses up to 50 kHz.
PDF p. 11
Analogue inputs
Two standard analogue inputs: 0–10 V or 0–20 mA.
PDF p. 11

Technical specifications

I/O expansion
The I/O expansion card adds four DI, two −10…+10 V AI and four DO.
PDF p. 11
Feedback options
Incremental-encoder, resolver and frequency-division PG cards are listed; closed loop requires compatible feedback hardware.
PDF p. 11

Communication and options

Communications
Modbus is standard; the current catalogue lists CANopen and Profinet as options.
PDF p. 13

Installation and cooling

Operating temperature
Nominal −10…+40 °C; derated operation to +50 °C, reducing rated output current 1.5% per degree above +40 °C.
PDF p. 11
Altitude and derating
0–3000 m; reduce rated output current by 1% per 100 m above 1000 m.
PDF p. 11
Environmental conditions
Relative humidity <95%, non-condensing; vibration <5.9 m/s²; storage −20…+60 °C.
PDF p. 11
Enclosure protection
IP20, forced-air cooling; clean, ventilated indoor installation.
PDF p. 11

Selection information

Long motor cables
The manual recommends an output AC reactor when motor cable length exceeds 100 m.
PDF p. 6
Output-capacitor caution
Do not connect power-factor correction capacitors to the drive output.
PDF p. 6

Model and dimension tables

Check the units and document revision in each table. Wide tables can be scrolled horizontally on small screens.

Model and current options

Select the motor and feedback board together with the heavy/light-duty current rating. Use the technical documentation for the ordered hardware revision.

Model codeSupply / voltage classMotor powerHeavy-duty output currentLight-duty currentSource
VFD530-R75GT4B3 phase, 380–480 V0.75 kW2.5 A4.2 APDF p. 8
VFD530-1R5GT4B3 phase, 380–480 V1.5 kW4.2 A5.6 APDF p. 8
VFD530-2R2GT4B3 phase, 380–480 V2.2 kW5.6 A9.4 APDF p. 8
VFD530-5R5G/7R5PT4B3 phase, 380–480 V5.5 kW13 A17 APDF p. 8
VFD530-7R5G/011PT4B3 phase, 380–480 V7.5 kW17 A23 APDF p. 8
VFD530-011G/015PT4B3 phase, 380–480 V11 kW25 A31 APDF p. 8
VFD530-015G/018PT4B3 phase, 380–480 V15 kW32 A37 APDF p. 8
VFD530-018G/022PT4B3 phase, 380–480 V18.5 kW37 A45 APDF p. 8
VFD530-022G/030PT4B3 phase, 380–480 V22 kW45 A57 APDF p. 8
VFD530-030G/037PT43 phase, 380–480 V30 kW60 A75 APDF p. 8
VFD530-037G/045PT43 phase, 380–480 V37 kW75 A87 APDF p. 8
VFD530-045G/055PT43 phase, 380–480 V45 kW90 A110 APDF p. 8
VFD530-055G/075PT43 phase, 380–480 V55 kW110 A135 APDF p. 8
VFD530-075G/090PT43 phase, 380–480 V75 kW152 A165 APDF p. 8
VFD530-090G/110PT43 phase, 380–480 V90 kW176 A210 APDF p. 8
Enclosure and mounting dimensions

Compare the full product code and enclosure drawing before installation. Dimensions can differ between hardware revisions.

ScopeWidthHeightDepthMounting pitchesHole diameterSource
0.75–4 kW100 mm215 mm170 mm87 × 206.5 mm5 mmPDF p. 19
5.5–7.5 kW130 mm250 mm180 mm113 × 239.5 mm5 mmPDF p. 19
11–15 kW170 mm310 mm193 mm153 × 299 mm6 mmPDF p. 19
18.5–22 kW210 mm370 mm205 mm165 × 350 mm6 mmPDF p. 19
30–37 kW260 mm452.5 mm230 mm218 × 438 mm7 mmPDF p. 19

Document revision and selection notes

The manual at the 2025 download URL is internally marked V1.0 / February 2021

The manual at the 2025 download URL is internally marked V1.0 / February 2021. Differences from the newer brochure are identified separately.
PDF p. 2

The 4R0 model code has a 3.7 kW motor-power cell in the manual

The 4R0 model code has a 3.7 kW motor-power cell in the manual. Do not silently normalise it to 4.0 kW without checking the nameplate.
PDF p. 8

VC starting torque is 200% in the manual but 180% in the brochure specification table; avoid an unconditional claim.

VC starting torque is 200% in the manual but 180% in the brochure specification table; avoid an unconditional claim.
PDF p. 10PDF p. 13

The V1.0 / 2021-02 manual specifies 3000 Hz V/f; the brochure linked in 2025 specifies 600 Hz

The V1.0 / 2021-02 manual specifies 3000 Hz V/f; the brochure linked in 2025 specifies 600 Hz. Manufacturer/firmware confirmation is required.
PDF p. 10PDF p. 13

The manual lists two relays, the brochure specification table one, while a separate IO2 page shows seven DI

The manual lists two relays, the brochure specification table one, while a separate IO2 page shows seven DI. These board configurations are not interchangeable.
PDF p. 11PDF p. 6PDF p. 13

The old manual calls CANopen/Profinet under development; the newer catalogue offers them as options

The old manual calls CANopen/Profinet under development; the newer catalogue offers them as options. Verify installed board and firmware.
PDF p. 10PDF p. 13

Important note 7

Conflicting/revision-specific document information; confirm the ordered unit: V1.0 manual: V/f 0–3000 Hz, SVC 0–200 Hz, VC 0–400 Hz; the V/f limit conflicts with the newer catalogue.
PDF p. 10

Important note 8

Conflicting/revision-specific document information; confirm the ordered unit: Manual: V/f 150% at 0.5 Hz, SVC 180% at 0.25 Hz, VC 200% at 0 Hz.
PDF p. 10

Important note 9

Conflicting/revision-specific document information; confirm the ordered unit: Manual: one digital output, one separate 50 kHz pulse output, two relays and two analogue outputs.
PDF p. 11

Manufacturer drawings

Open connection and dimension drawings in the manufacturer’s original PDF. For installation, use the complete manual matching the exact product model.

Open drawing in PDF
VFD530 — enclosure and mounting dimensions
PDF p. 19

Information needed for selection

Providing the following information helps our technical team select the correct product and accessories.

  • What does the complete motor nameplate state: phase, voltage, rated current, power and motor type?
  • What starting torque, braking requirement and duty cycle does the load require?
  • Will control use terminals, an analogue signal, communications or encoder feedback?
  • What are the cabinet temperature, altitude, motor-cable length and available mounting space?

Let us verify your application

For VFD530 High Performance AC Drive selection, share motor, supply, control, environment and duty-cycle data with our engineering team.