Skip to Content
Veikong · Reactors

AC Output Reactor

The OCL 4% output reactor is installed between the drive and motor. It helps smooth output current and reduce dv/dt, motor noise and leakage-current effects. Its 380 V selection table gives model-specific current and inductance; motor operating frequency must also be checked.

Veikong series representative image

Reactor-family representative image — not an exact photo of the selected current class.

Technical specifications

Ratings refer to the linked document revision. Confirm the nameplate, motor current and operating conditions for the exact selection.

Technical specifications

Location
Drive → reactor → motor
PDF p. 2
Impedance rate
4%
PDF p. 2
Rated voltage
400 V
PDF p. 2
Frequency
0–120 Hz operation; >120 Hz on request
PDF p. 2
Rated current
5–1600 A
PDF p. 2
Ambient temperature
−25…+50 °C
PDF p. 2
Protection
IP00
PDF p. 2
Insulation class
F / H
PDF p. 2
Noise (1 m)
<80 dB
PDF p. 2
Dielectric test
AC 3000 V, 50 Hz, 5 mA, 60 s
PDF p. 2

Technical specifications

Standards stated in datasheet
GB19212.1-2008; GB/T1094.6-2011
PDF p. 2

Model and dimension tables

Check the units and document revision in each table. Wide tables can be scrolled horizontally on small screens.

380 V / 4% selection table
ModelPower (kW)Current (A)Inductance (mH)Weight (kg)ConnectionCopper bar (mm)ApertureFigureSource
OCL-0005-CL/4-41.555.61.6TerminalNot specifiedNot specifiedAPDF p. 3
OCL-0007-CL/4-42.2742TerminalNot specifiedNot specifiedAPDF p. 3
OCL-0010-CL/4-43.7102.82.5TerminalNot specifiedNot specifiedAPDF p. 3
OCL-0015-AL/4-45.5151.873.5TerminalNot specifiedNot specifiedAPDF p. 3
OCL-0020-AL/4-47.5201.44TerminalNot specifiedNot specifiedAPDF p. 3
OCL-0030-AL/4-411300.9346TerminalNot specifiedNot specifiedAPDF p. 3
OCL-0040-AL/4-415400.77.5TerminalNot specifiedNot specifiedBPDF p. 3
OCL-0050-AL/4-418.5500.5611.5TerminalNot specifiedNot specifiedBPDF p. 3
OCL-0060-AL/4-422600.46712TerminalNot specifiedNot specifiedBPDF p. 3
OCL-0080-AL/4-430800.3515TerminalNot specifiedNot specifiedBPDF p. 3
OCL-0090-AL/4-437900.31115TerminalNot specifiedNot specifiedBPDF p. 3
OCL-0120-AL/4-4451200.23319.5Copper bar25*3φ9CPDF p. 3
OCL-0150-AL/4-4551500.18723Copper bar30*6φ11DPDF p. 3
OCL-0200-AL/4-4752000.1428Copper bar30*6φ11DPDF p. 3
OCL-0240-AB/4-4902400.11738Copper bar30*8φ11EPDF p. 3
OCL-0260-AB/4-41102600.10839Copper bar30*8φ11EPDF p. 3
OCL-0290-AB/4-41322900.09740Copper bar40*7φ13EPDF p. 3
OCL-0330-AB/4-41603300.08545.5Copper bar40*7φ13EPDF p. 3
OCL-0390-AB/4-41853900.07255Copper bar40*8φ13EPDF p. 3
OCL-0420-AB/4-42004200.06756Copper bar40*8φ13EPDF p. 3
OCL-0490-AB/4-42204900.05765Copper bar50*82-φ13FPDF p. 3
OCL-0530-AB/4-42505300.05365Copper bar50*82-φ13FPDF p. 3
OCL-0600-AB/4-42806000.04773Copper bar50*92-φ13GPDF p. 3
OCL-0660-AB/4-43156600.04273Copper bar50*92-φ13GPDF p. 3
OCL-0800-AB/4-43808000.03583Copper bar60*94-φ13HPDF p. 3
OCL-1000-AB/4-445010000.028110Copper bar60*114-φ13HPDF p. 3
OCL-1250-AB/4-455012500.0225130Copper bar60*134-φ13HPDF p. 3
OCL-1600-AB/4-463016000.0175180Copper bar80*134-φ13HPDF p. 3
Model dimensions (mm)

A–B drawings: p.3; C–H drawings: p.4.

ModelFigureD maxD1 ±1D2 ±2W ±10W1 ±1W2 ±2H maxMounting A×BSource
OCL-0005-CL/4-4A1003580Not specified52701257x12PDF p. 3
OCL-0007-CL/4-4A1003580Not specified59771257x12PDF p. 3
OCL-0010-CL/4-4A1003580Not specified75931257x12PDF p. 3
OCL-0015-AL/4-4A15070120Not specified77971607x12PDF p. 3
OCL-0020-AL/4-4A15070120Not specified77971607x12PDF p. 3
OCL-0030-AL/4-4A18070145Not specified901101707x12PDF p. 3
OCL-0040-AL/4-4B180701451601021221407x12PDF p. 3
OCL-0050-AL/4-4B205801701651051251607x12PDF p. 3
OCL-0060-AL/4-4B205801701651051251607x12PDF p. 3
OCL-0080-AL/4-4B210801701801121321907x12PDF p. 3
OCL-0090-AL/4-4B210801701801121321907x12PDF p. 3
OCL-0120-AL/4-4C205801701701201402157x12PDF p. 3
OCL-0150-AL/4-4D2458020017511014021010x16PDF p. 3
OCL-0200-AL/4-4D2458020019513016021010x16PDF p. 3
OCL-0240-AB/4-4E31022525019511915528012x20PDF p. 3
OCL-0260-AB/4-4E31022525019511915528012x20PDF p. 3
OCL-0290-AB/4-4E31022525021012416028012x20PDF p. 3
OCL-0330-AB/4-4E31022525022013417028012x20PDF p. 3
OCL-0390-AB/4-4E31022525024515919528012x20PDF p. 3
OCL-0420-AB/4-4E31022525024515919528012x20PDF p. 3
OCL-0490-AB/4-4F31022525028017921528012x20PDF p. 3
OCL-0530-AB/4-4F31022525028017921528012x20PDF p. 3
OCL-0600-AB/4-4G39013032029522026035012x20PDF p. 3
OCL-0660-AB/4-4G39013032029522026035012x20PDF p. 3
OCL-0800-AB/4-4H39013032033023527535012x20PDF p. 3
OCL-1000-AB/4-4H39013032034525529541012x20PDF p. 3
OCL-1250-AB/4-4H39013032038029033041012x20PDF p. 3
OCL-1600-AB/4-4H45015038039528532546012x20PDF p. 3

Document revision and selection notes

Insulation resistance is >100 MΩ in English but ≥100 MΩ in Chinese (DC 1000 V).

Insulation resistance is >100 MΩ in English but ≥100 MΩ in Chinese (DC 1000 V).
PDF p. 2

The general rating says 400 V while the selection table says 380 V

The general rating says 400 V while the selection table says 380 V. Cable lengths on the first-page diagram belong to different reactor/filter topologies and are not guarantees for the 4% OCL model.
PDF p. 1PDF p. 2PDF p. 3

Manufacturer drawings

Open connection and dimension drawings in the manufacturer’s original PDF. For installation, use the complete manual matching the exact product model.

Open drawing in PDF
C–H connection and mounting drawings
PDF p. 4

Information needed for selection

Providing the following information helps our technical team select the correct product and accessories.

  • Have drive voltage, continuous/overload current and required impedance been confirmed?
  • What are the motor frequency, cable length and drive-maker reactor requirements?

Let us verify your application

For AC Output Reactor selection, share motor, supply, control, environment and duty-cycle data with our engineering team.

Request a technical review