Skip to Content
Veikong · Reactors

DC Reactor

The DCL reactor smooths ripple in a drive’s DC link and helps limit pulse-current stress on the rectifier and capacitors. Its datasheet provides model-specific current, inductance, connections and mounting dimensions for 400 V-class inverters; motor power alone is not a complete selection criterion.

Veikong series representative image

Reactor-family representative image — not an exact photo of the selected current class.

Technical specifications

Ratings refer to the linked document revision. Confirm the nameplate, motor current and operating conditions for the exact selection.

Technical specifications

Location
Drive DC link
PDF p. 1
Rated voltage
DC 500–1000 V
PDF p. 1
Insulation class
F / H option
PDF p. 1
Noise
<65 dB; measured horizontally at 1 m
PDF p. 1
Dielectric test
Core–winding: AC 3000 V, 50 Hz, 5 mA, 60 s
PDF p. 1
Construction
Foil winding; cold-rolled silicon-steel core
PDF p. 1

Technical specifications

Standards stated in datasheet
GB19212.1-2008; GB/T1094.6-2011
PDF p. 1

Model and dimension tables

Check the units and document revision in each table. Wide tables can be scrolled horizontally on small screens.

Selection for 400 V inverters
ModelInverter power (kW)Current (A)Inductance (mH)ConnectionWeight (kg)FigureSource
DCL-0003-AL/40.4/0.75328Terminal0.9APDF p. 3
DCL-0006-AL/41.5/2.2611Terminal1.1APDF p. 3
DCL-0012-AL/43.7/4.0126.3Terminal2.1APDF p. 3
DCL-0023-AL/45.5/7.5233.6Terminal3.8BPDF p. 3
DCL-0033-AL/411/15332Terminal4BPDF p. 3
DCL-0040-AL/418.5401.3Terminal3.8BPDF p. 3
DCL-0050-AL/422501.08Terminal4.9CPDF p. 3
DCL-0065-AL/430650.8Terminal6CPDF p. 3
DCL-0078-AL/437780.7Terminal8CPDF p. 3
DCL-0095-AL/445950.54Terminal9.5CPDF p. 3
DCL-0115-AL/4551150.45Copper connection; hole Φ1111DPDF p. 3
DCL-0160-AL/4751600.36Copper connection; hole Φ1116DPDF p. 3
DCL-0180-AL/4901800.33Copper connection; hole Φ1116DPDF p. 3
DCL-0250-AB/4110/1322500.26Copper connection; hole Φ1325EPDF p. 3
DCL-0340-AB/41603400.17Copper connection; hole Φ1325EPDF p. 3
DCL-0460-AB/4185/2204600.09Copper connection; hole Φ1325EPDF p. 3
DCL-0650-AB/4250/3156500.072Copper connection; hole Φ1337EPDF p. 3
DCL-1000-AB/4380/40010000.046Copper connection; hole Φ1347FPDF p. 3
DCL-1250-AB/450012500.022Copper connection; hole Φ1351GPDF p. 3
DCL-1500--AB/463015000.016Copper connection; hole Φ1152HPDF p. 3
DCL-1800--AB/472018000.012Copper connection; hole Φ1152HPDF p. 3
Model dimensions (mm)

Read dimension letters and tolerances with the applicable A–H drawing; / does not mean zero.

ModelFigureDD1D2HWW1W2Mounting A×BSource
DCL-0003-AL/4A5747.5Not specified85Not specified68884.5*7PDF p. 3
DCL-0006-AL/4A7664Not specified105Not specified56765x8PDF p. 3
DCL-0012-AL/4A7664Not specified105Not specified851055x8PDF p. 3
DCL-0023-AL/4B11495Not specified145Not specified901107x12PDF p. 3
DCL-0033-AL/4B11495Not specified145Not specified951157x12PDF p. 3
DCL-0040-AL/4B11495Not specified145Not specified901107x12PDF p. 3
DCL-0050-AL/4C11495Not specified1001651051257x12PDF p. 3
DCL-0065-AL/4C11495Not specified1001801201407x12PDF p. 3
DCL-0078-AL/4C133111Not specified1151901201407x12PDF p. 3
DCL-0095-AL/4C133111Not specified1152051351557x12PDF p. 3
DCL-0115-AL/4D168140Not specified1451851201408x14PDF p. 3
DCL-0160-AL/4D168140Not specified1452051401608x14PDF p. 3
DCL-0180-AL/4D168140Not specified1452051401608x14PDF p. 3
DCL-0250-AB/4E21016020026521012015611x20PDF p. 3
DCL-0340-AB/4E21016020026521012015611x20PDF p. 3
DCL-0460-AB/4E21016020026521012015611x20PDF p. 3
DCL-0650-AB/4E22016020031526514017611x20PDF p. 3
DCL-1000-AB/4F26518024031026515518512x18PDF p. 3
DCL-1250-AB/4G26018024032527516219212x20PDF p. 3
DCL-1500--AB/4H26018024036027014017012x20PDF p. 3
DCL-1800--AB/4H26018024036027014017012x20PDF p. 3

Document revision and selection notes

Insulation resistance is >100 MΩ in English but ≥100 MΩ in Chinese (DC 1000 V); confirm the exact acceptance threshold.

Insulation resistance is >100 MΩ in English but ≥100 MΩ in Chinese (DC 1000 V); confirm the exact acceptance threshold.
PDF p. 1

The power matches below belong to the 400 V inverter table, not every application across the DC 500–1000 V range.

The power matches below belong to the 400 V inverter table, not every application across the DC 500–1000 V range.
PDF p. 3

The source uses a double hyphen in the 1500 A and 1800 A model codes; these have not been silently corrected.

The source uses a double hyphen in the 1500 A and 1800 A model codes; these have not been silently corrected.
PDF p. 3

Manufacturer drawings

Open connection and dimension drawings in the manufacturer’s original PDF. For installation, use the complete manual matching the exact product model.

Open drawing in PDF
A–E body and mounting drawings
PDF p. 2

Information needed for selection

Providing the following information helps our technical team select the correct product and accessories.

  • Does the drive provide external DC-reactor terminals, and what DC current, voltage class and inductance are required?

Let us verify your application

For DC Reactor selection, share motor, supply, control, environment and duty-cycle data with our engineering team.

Request a technical review