Skip to Content
XB6S-PL20
Solidot · Pulse Counter Module

XB6S-PL20

The new generation of slice incremental encoder counting modules, using the X-bus backplane bus, can externally connect two 24V single-ended incremental encoders. The module supports functions such as Z-phase clearing, comparison output, and probe latching. Paired with our company's XB6S series couplers, it can be widely used in various industrial system equipment.

Pulse Counter Module
Input Channel Voltage Rated Value (Range)24VDC(15V~30V)
Channel TypeEncoder input channels: 2 sets of channels (Phase A, Phase B and Phase Z), PNP/NPNProbe input channels: 4 channels (1 encoder matched with 2 probe functions), PNP/NPNGeneral digital input channels: 4 channels (1 encoder matched with 2 general digital inputs), PNP/NPNComparison output channel: 4 Channels (1 encoder matched with 2 comparison outputs), NPNGeneral digital output channel: 4 Channels (1 encoder matched with 2 general digital outputs), NPN
Real-time speed of reporting channelSupport

What defines this model

Review the published differences attached to this exact model code rather than only the general family.

Published capability

24V-NPN/PNP single-ended, supports real-time speed reporting of two encoder channels

Published capability

Supports AB phase (ABZ), direction pulse (Pul+Dir), dual pulse (CW/CCW)

Published capability

Supports outputting adjustable pulse signals when the count value reaches the set value on corresponding output channel

Published capability

Supports latching current count value when voltage changes occur in probe input pins

Place in the system architecture

Treat network, product and field layers as one validation flow.

Control architecture

Network and host-controller compatibility

Complete model code

Channel, interface and function selection

Electrical and installation

Power, connection, environment and mechanical layout

Technical parameters

Values come from Solidot's current official model record and must be reconfirmed for the product revision.

Interface Parameters
Refresh Rate1ms
Connection MethodReed Contact
Process data volume: Downlink20Bytes
Process data volume: Upstream34Bytes
Data Transfer Rates6Mb/s
Electrical IsolationYes
Technical Parameters
System Power Input5VDC(4.5V~5.5V)
Field Power Supply Rated Value (Range)24VDC(18V~36V)
Input Channel Voltage Rated Value (Range)24VDC(15V~30V)
Module Abnormality Self-Recoverysupport
diagnosissupport
Alarmsupport
Firmware Upgradesupport
Operating Temperature-20℃~+60℃
Relative Humidity95%,no condensation
Storage Temperature-40℃~+80℃
Protect. ClassIP20
Module Size106.4×25.7×72.3mm
Weight110g
Functional Parameters
Channel TypeEncoder input channels: 2 sets of channels (Phase A, Phase B and Phase Z), PNP/NPNProbe input channels: 4 channels (1 encoder matched with 2 probe functions), PNP/NPNGeneral digital input channels: 4 channels (1 encoder matched with 2 general digital inputs), PNP/NPNComparison output channel: 4 Channels (1 encoder matched with 2 comparison outputs), NPNGeneral digital output channel: 4 Channels (1 encoder matched with 2 general digital outputs), NPN
Power supply voltage24VDC(18V~36V)
Probe latch functionSupport
Compare output functionSupport
Encoder pulse input modeAB Orthogonal (ABZ), Directional Pulse (Pul+Dir), Dual Pulse (CW/CCW)
Maximum input frequency of encoder pulses1MHz
Real-time speed of reporting channelSupport
Reset Z-axis to zeroSupport
Counting rate setting4x / 2x / 1x (default 1x)
Circular countingSupport
Counting Range0~2^32-1 or 0~ring counter resolution × count rate -1
Encoder resolution settingSupport (the setting range for ring count resolution is 1~65535)
Setting the initial value of the counterSupport (the range for setting the initial count value is 0~2^32-1)
Reverse countingSupport
Encoder input hardware filteringSupport (Level 0~15)
Probe input frequency1MHz
Compare the response speed of output signals<10us
Input/output pin function selectionSupport
Power failure storageSupport

Product images

Images are official source records for the same model.

Frequently asked questions

Core checks before selection and commissioning.

Which industrial network does XB6S-PL20 support?

Network support must be confirmed from the exact model code and current official documentation.

What are the principal published specifications?

Input Channel Voltage Rated Value (Range): 24VDC(15V~30V); Channel Type: Encoder input channels: 2 sets of channels (Phase A, Phase B and Phase Z), PNP/NPNProbe input channels: 4 channels (1 encoder matched with 2 probe functions), PNP/NPNGeneral digital input channels: 4 channels (1 encoder matched with 2 general digital inputs), PNP/NPNComparison output channel: 4 Channels (1 encoder matched with 2 comparison outputs), NPNGeneral digital output channel: 4 Channels (1 encoder matched with 2 general digital outputs), NPN; Real-time speed of reporting channel: Support; System Power Input: 5VDC(4.5V~5.5V)

How should this model be selected?

Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.

Other models in this category

Compare protocol, channel architecture and environmental limits.

Manufacturer source

Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record

Validate the right Solidot XB6S-PL20 architecture with ProControl

Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.

Contact engineering