Occupies fewer nodes, one coupler supports up to 32 slots and 1024 points

XB6S-PN2002
PROFINET Coupler: built-in Ethernet switch, 2-way ethercat bus interface, and 1-way backplane X-bus interface, 106*61*47mm, can provide 2000mA drive current for coupler and subsequent IO modules. space saving, smart, fast wiring, RTB(Removable Terminal Block), easy configuration, suitable for Siemens 1200,1500, Codesys and other PROFINET main stations, high speed X-bus, full load 32 slave stations, scanning cycle as low as 1ms, IP20.
What defines this model
Review the published differences attached to this exact model code rather than only the general family.
Supports flexible expansion and configuration, can integrate digital, analog, motion control modules etc.
The communication interface complies with communication standards, supporting mainstream PROFINET master station such as Siemens
Uses X-bus backplane bus: minimum scan cycle is 200us, typical value is 1ms
Place in the system architecture
Treat network, product and field layers as one validation flow.
Control network and backplane bus
Digital, analogue, temperature and special-function channels
Power, wiring and field-device matching
Technical parameters
Values come from Solidot's current official model record and must be reconfirmed for the product revision.
Interface Parameters
| Minimum Cycle Time | 1ms |
|---|---|
| Input and output process data volume | 1024Bytes |
| Protocol | PROFINET |
| Max. Number of IO Modules | 32 |
| Data Transfer Medium | Ethernet CAT5 cable |
| Bus Interface | 2*RJ45 |
| Data Transfer Rates | 100Mb/s |
| Distance Between Stations | 100m(station to station) |
Technical Parameters
| MRP | Support |
|---|---|
| Module Abnormality Self-Recovery | Support |
| diagnosis | Support |
| Alarm | Support |
| Firmware Upgrade | Support |
| Operating Temperature | -20~60℃ |
| Power Supply | 24VDC(18V~36V) |
| Relative Humidity | 95 %, no condensation |
| Storage Temperature | -40~80℃ |
| Protect. Class | IP20 |
| Module Size | 106.4*43*61mm |
| Weight | 160g |
| Power Interface | 3 pin |
Product images
Images are official source records for the same model.

Official files
Only links published by the manufacturer for this model are listed.
Frequently asked questions
Core checks before selection and commissioning.
Which industrial network does XB6S-PN2002 support?
Published network support: EtherCAT, PROFINET. Confirm controller compatibility and the complete order code before commissioning.
What are the principal published specifications?
Protocol: PROFINET; Bus Interface: 2*RJ45; Power Interface: 3 pin; Minimum Cycle Time: 1ms
How should this model be selected?
Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.
Other models in this category
Compare protocol, channel architecture and environmental limits.
Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record
Validate the right Solidot XB6S-PN2002 architecture with ProControl
Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.