XB6-A40TDC is a temperature control module that supports thermistor sensors. It uses the X-bus bottom bus and is compatible with our company's XB6 series coupler modules, capable of real-time temperature data collection and high-precision temperature control.

Temperature Module
Control Cycle4 channels 200ms
Sensor input temperature accuracy±0.5℃
Analog Inputs4

What defines this model

Review the published differences attached to this exact model code rather than only the general family.

Published capability

Rich in measurement types, supports sensor type selection

Published capability

Each channel supports disconnection detection

Published capability

Sensitivity: 0.1℃, suppresses 50Hz AC power interference

Published capability

Heating control self-tuning function, using a proprietary PID independent control algorithm

Place in the system architecture

Treat network, product and field layers as one validation flow.

Coupler

Control network and backplane bus

I/O modules

Digital, analogue, temperature and special-function channels

Terminals and devices

Power, wiring and field-device matching

Technical parameters

Values come from Solidot's current official model record and must be reconfirmed for the product revision.

Interface Parameters
Data Transfer MediumX-Bus backplane bus
Data Transfer Rates6Mb/s
Technical Parameters
Current Consumption80mA
Sensor wire2、3
Sensor input temperature accuracy±0.5℃
Sensitivity0.1℃
Sensor Sampling Period4 channels 130ms
Control PrecisionMaximum Deviation 2℃,normally ±0.5℃
Control Cycle4 channels 200ms
Disconnection detectionsupport
Disconnection detection time2ms
Output signalPWM Output (SSR Output)
Overflow functionsupport
Operating Temperature-10~60℃
Power SupplyPower supply via X-Bus
Relative Humidity95 %, no condensation
Storage Temperature-20~75℃
Protect. ClassIP20
Module Size106*73*25.7 mm
Weight120g
Analog
Sensor TypeRTD
Analog Inputs4
Resolution24 bit(int type)
IndicatorGreen LED

Product images

Images are official source records for the same model.

Frequently asked questions

Core checks before selection and commissioning.

Which industrial network does XB6-A40TDC support?

Network support must be confirmed from the exact model code and current official documentation.

What are the principal published specifications?

Control Cycle: 4 channels 200ms; Sensor input temperature accuracy: ±0.5℃; Analog Inputs: 4; Output signal: PWM Output (SSR Output)

How should this model be selected?

Evaluate network, channel function, power, environment, wiring and mechanical placement as one configuration. ProControl can verify the final bill of materials.

Other models in this category

Compare protocol, channel architecture and environmental limits.

Manufacturer source

Technical data and images are based on the current official Solidot product record. Verify revision-sensitive values before ordering or commissioning. Open official record

Validate the right Solidot XB6-A40TDC architecture with ProControl

Share the network, signal count, environment and installation constraints; our engineering team will review the complete configuration.

Contact engineering